Construction: The interior of the T.O.P drip head consists of 12 zones. Each zone is controlled by an individual self-flushing, pressure compensating, color-coded nozzle with an "o" ring. Each nozzle is constructed of an inlet and outlet, made of plastic, with a soft silicon diaphragm between them. The inlet area of each nozzle has four (4) regulating grooves which serve as a secondary filter of approximately 80 mesh. These secondary filters are in addition to the primary Mini disk filter that sits above. Each nozzle should be color coded with black representing 0.6 gph, red representing 1 gph, green representing 2.2 gph and purple representing 3.3 gph. Nozzles of different flow rates may be combined in a single T.O.P. head.
Operation: Each nozzle has the ability to regulate outflow independently with an inlet working pressure range of eight to eighty psi (8 -80 psi). At a constant outflow rate, the manufacturer's coefficient of variation (CV) is .07 for 1 gph, .03. for 2.2 gph and .01 for 3.3 gph. Below 8 psi the nozzle is in self flushing mode. Minimum pressure at the last T.O.P. head should not drop below 10 psi to ensure the proper function of the self flushing mode. The T.O.P. drip emitter has a 1/8" outlet that may be attached to any distribution tubing with anoutside diameter between .178" and .190" , or with the addition of a color coded converter barb or elbow at may attach to 1/4" distribution tubing with an inside diameter between .150 " and .160".
 
Model Available
  • Model TOP- 005 T.O.P. 12 Zone Drip Head, .6 gph per zone
  • Model TOP- 010 T.O.P. 12 Zone Drip Head, 1 gph per zone
  • Model TOP- 020 T.O.P. 12 Zone Drip Head , 2.2 per zone
  • Model TOP- 030 T.O.P. 12 Zone Drip Head, 3.3 gph per zone
Performance Characteristics
  • Operating pressure: 8 - 80 psi
  • Recommended operating pressure: 10 to 45 PSI
  • Recommended filtration at the valve assembly: 120 mesh
  • Flow rates: .6, 1, 2.2, and 3.3 gph per zone
  • Manufacture coefficient of variation (CV): 1 gph .07, 2.2 gph .03 and 3.3 gph .01
  • Secondary filtration of approximately 80 mesh at each nozzle