- CIT drip emitters
evaluation
- Emitter flow rate .6 gph
-
- Emitter flow rate 1 gph
- Number tested 6

|
PRES. |
TEMP |
MEAN |
STD DEV. |
CV |
EU |
CU |
|
55 |
69.8 |
0.99 |
0.06 |
0.062 |
94% |
95% |
|
60 |
69.8 |
0.99 |
0.07 |
0.071 |
93% |
95% |
|
65 |
69.8 |
0.98 |
0.07 |
0.075 |
92% |
94% |
|
70 |
69.8 |
0.96 |
0.08 |
0.081 |
92% |
94% |
|
75 |
69.8 |
0.96 |
0.09 |
0.092 |
89% |
93% |
|
80 |
69.8 |
0.98 |
0.13 |
0.133 |
83% |
89% |
- Emitter flow rate 2.2 gph
- Number tested 6

|
PRES. |
TEMP |
MEAN |
STD DEV. |
CV |
EU |
CU |
|
55 |
69.8 |
2.21 |
0.03 |
0.013 |
97% |
99% |
|
60 |
69.8 |
2.21 |
0.03 |
0.013 |
985 |
99% |
|
65 |
69.8 |
2.20 |
0.05 |
0.023 |
96% |
98% |
|
70 |
69.8 |
2.19 |
0.06 |
0.029 |
96% |
98% |
|
75 |
69.8 |
2.17 |
0.08 |
0.038 |
96% |
97% |
|
80 |
69.8 |
2.15 |
0.09 |
0.042 |
96% |
97% |
- Emitter flow rate 3.3
gph
- Number
tested 6

|
PRES. |
TEMP |
MEAN |
STD DEV. |
CV |
EU |
CU |
|
55 |
69.8 |
3.59 |
0.05 |
0.014 |
98% |
99% |
|
60 |
69.8 |
3.57 |
0.05 |
0.018 |
98% |
99% |
|
65 |
69.8 |
3.51 |
0.03 |
0.009 |
99% |
99% |
|
70 |
69.8 |
3.45 |
0.03 |
0.010 |
99% |
99% |
|
75 |
69.8 |
3.39 |
0.05 |
0.015 |
98% |
99% |
|
80 |
69.8 |
3.32 |
0.07 |
0.022 |
98% |