Troubleshooting: LEIT-2 & LEIT RC2

If difficulties occur when installing or maintaining a LEIT-2 system, please review this online LEIT Troubleshooting Guide. It contains useful information designed to help identify the specific cause, as well as step-by-step instructions that may help to correct the problem.

The LEIT-2 irrigation control system is a series of connected components consisting of 2 station ambient light powered irrigation controller, LEIT remote handset 2 wire S-305 DC soleniod and hydraulic control valves. It is best to troubleshoot this DC system (like an AC system) by a process of elimination; the goal being to determine which component(s) has failed. The following facts and tips may be helpful to eliminate certain components and facilitate faster troubleshooting. It is assumed that these are installed controllers that are receiving the proper amount of light.

  1. The Leit-2 wireless irrigation controller needs adequate light. The radio cannot maintain proper functionality in a continually shaded position, such as adjacent to a wall, unless it is on the "sunny" side of the wall. If light levels drop too low the radio will turn it off to guarantee correct controller operation. When the radio is off, less power is used and the controller charges faster. The radio's internal circuitry can turn itself on again when sufficient light has charged the controller to adequate levels. At low light levels the radio will periodically turn off.
  2. The radio will function better if the controller is located at higher elevation. If there is a choice do not situate the controller in a hollow.
  3. To communicate, the controller and handsets MUST have the same Client ID Code. This is the users identification code, which prevents interference from other users in the area.
  4. If two controllers are set to the same ID, communication may be disrupted if both controllers are in range of the handset. The same occurs if two handsets are set to the same ID and are in use at the same time. All controllers and handsets in the same group must have a unique ID.
  5. The handset needs to be kept in a charged state. After 500-1000 charge cycles the internal batteries may need replacement.

    Programming Problems: LEIT-2 & LEIT RC2

  • Programming Quick Reference Chart
  • The valves will turn on using the "Manual Run" feature but will not water automatically
  • No communication

    Controller: LEIT-2 & LEIT RC2

  • Troubleshooting Controller

    S-305DC Solenoids

  • Troubleshooting the S-305DC Solenoids