Products -> Drip Emitters -> Pressure Compensating Dripper

Pressure Compensating Dripper

FEATURES:

  • Suggested operating pressure is 10 to 55 PSI
  • Available in 1, 2 and 4 GPH
  • Color coded for easy identification
  • Large water passage reduces clogging
  • Available in packs of 10 and in our kits, models FM01AS, G77AS and GE200
  • Flow rates 2 GPH and below meet all city and county water restrictions
  • Filter requirement: 155 mesh
Max Run of 1/4" Micro Tubing or 1/2" Poly Tubing with PC Drip Emitters
Drip Emitter & Flow Rate Drip Emitter Spacing in Feet
1/4" Micro Tubing
Drip Emitter Spacing in Feet
.600 ID x .700 OD, 1/2" Micro Tubing
ModelLocator #Flow1'2'3'4'5'1'2'3'4'5'
B221B301 GPH35507288105320530670820970
B222B382 GPH2536455665190310450510610
B224B344 GPH1422303640120200250320450
Model Locator Unit Pack Color Code description
B221B 30 10 Black 1 GPH
B224B 34 10 Red/Black 4 GPH
B222B 38 10 Green/Blac 2 GPH
Pressure Compensating Dripper